100W Co2 Laser Power Supply for CO2 Laser Engraving and Cutting Machine MYJG-100
Product Features:
1.This laser power supply adopts zero current and half bridge soft switch circuit, it makes the power supply have high efficiency and quick response speed, Thus it is easy to match with Co2 laser tube made by various factories.
2.This laser power supply is easy to be controlled, it is suitable to High or Low level signal. The TTL level can control start or stop of laser output. While the power supply has emergency protection switch which can indicate water through and ventilation.
3.The laser output power can be adjusted by 0-5V analog signal or PWM signal.
4.This laser power supply has open circuit protection function. When protective earthing is good, the laser power supply has open circuit protection function. When protective earthing is good, the laser power supply can be in open circuit status during short time. So that can avoid because of laser tube burst caused by laser power supply.
5.Aging test:
Each laser power supply must pass this test which is taken at 60 degree centigrade for 12 hours in full load status, and the power supply must start and stop at each 7 seconds for 500 times. In this way we can ensure the power supply is qualified.
Main Technical Parameters:
Connection Between Laser Tube and Power Supply:
Connection between Power Supply and Controller:
1.This laser power supply adopts zero current and half bridge soft switch circuit, it makes the power supply have high efficiency and quick response speed, Thus it is easy to match with Co2 laser tube made by various factories.
2.This laser power supply is easy to be controlled, it is suitable to High or Low level signal. The TTL level can control start or stop of laser output. While the power supply has emergency protection switch which can indicate water through and ventilation.
3.The laser output power can be adjusted by 0-5V analog signal or PWM signal.
4.This laser power supply has open circuit protection function. When protective earthing is good, the laser power supply has open circuit protection function. When protective earthing is good, the laser power supply can be in open circuit status during short time. So that can avoid because of laser tube burst caused by laser power supply.
5.Aging test:
Each laser power supply must pass this test which is taken at 60 degree centigrade for 12 hours in full load status, and the power supply must start and stop at each 7 seconds for 500 times. In this way we can ensure the power supply is qualified.
Main Technical Parameters:
put |
Input Voltage |
AC220V(Need AC110V ,please specify ,when order) |
||
AC frequency |
47 - 440HZ |
|||
Max Input power |
440W |
|||
Max Input current |
3A |
|||
Output |
Max output voltage |
DC35KV |
||
Max output current |
DC28mA | |||
Efficiency |
>/=90%(Full load) |
|||
MTBF |
>/=10000 Hours |
|||
Response speed |
≤ 1ms (Time from the TTL Signal is given to the output current up to 90% pre-setting current) |
|||
Withstand Voltage |
Input-Output, Input-Enclosure: AC1500V 10mA 60S, Output cathode is connected with enclosure. |
|||
Environment |
Operating temperature: (-10-40)degree Celsius,Relative humidity: ≤90% |
|||
Cooling |
Forced air cooling (fan cooling) |
Connection Between Laser Tube and Power Supply:

Connection between Power Supply and Controller: